{"id":4558,"date":"2018-01-11T21:10:00","date_gmt":"2018-01-11T20:10:00","guid":{"rendered":"https:\/\/www.climaset.it\/gld-series-refrigerant-gas-detectors\/"},"modified":"2026-02-23T11:00:38","modified_gmt":"2026-02-23T10:00:38","slug":"gld-small-refrigerant-gas-detectors","status":"publish","type":"post","link":"https:\/\/www.climaset.it\/en\/gld-small-refrigerant-gas-detectors\/","title":{"rendered":"GLD small refrigerant gas detectors"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"4558\" class=\"elementor elementor-4558 elementor-4536\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3c6f307 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3c6f307\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7577286\" data-id=\"7577286\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f0f285e elementor-widget elementor-widget-text-editor\" data-id=\"f0f285e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The new range of <strong>GLD Small<\/strong> series gas sensors has been designed for:<\/span><\/span> <\/span><\/p>\n<ul>\n<li><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\"><strong>comply with<\/strong> <em>EN 378<\/em> and <em>F-GAS<\/em> <strong>standards<\/strong>,<\/span><\/span><\/span><\/li>\n<li><span class=\"HwtZe\" lang=\"en\"> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\"><strong>avoid downtime<\/strong> or significant economic damage due to poor conservation<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">food,<\/span><\/span><\/span><\/li>\n<li><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">contribute to the <strong>reduction of<\/strong> greenhouse gas <strong>emissions<\/strong>,<\/span><\/span> <\/span><\/li>\n<li><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">provide for <strong>continuous monitoring<\/strong> of the environment where the refrigeration units are located,<\/span><\/span><\/span><\/li>\n<li><span class=\"HwtZe\" lang=\"en\"> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">ensure the <strong>safety of people<\/strong> who are in the proximity of the unit.<\/span><\/span><\/span><\/li>\n<\/ul>\n<p><span class=\"HwtZe\" lang=\"en\"> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The range of GLD small sensors allows connection to BOSS series supervision systems through a Modbus RTU RS-485 serial.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">When the <strong>leak is detected with settable thresholds<\/strong>, the sensor sends a digital or analog signal to the controller or supervisor connected to it.<\/span><\/span> <\/span><\/p>\n<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">The alarm can also be displayed locally with an acoustic and visual signal (optional accessory).<\/span><\/span><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-60ea1c1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"60ea1c1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-92f28ef\" data-id=\"92f28ef\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-45765e4 elementor-widget elementor-widget-image\" data-id=\"45765e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"582\" height=\"248\" src=\"https:\/\/www.climaset.it\/files\/2018\/01\/sensori-gas-gdl-small-carel-HD-1.jpg\" class=\"attachment-large size-large wp-image-8020\" alt=\"Photo of two Carel GLD small gas leakage detectors, with wired or built-in probe.\" srcset=\"https:\/\/www.climaset.it\/files\/2018\/01\/sensori-gas-gdl-small-carel-HD-1.jpg 582w, https:\/\/www.climaset.it\/files\/2018\/01\/sensori-gas-gdl-small-carel-HD-1-300x128.jpg 300w\" sizes=\"auto, (max-width: 582px) 100vw, 582px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-abb6d73 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"abb6d73\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f4ca207\" data-id=\"f4ca207\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-acd57f9 elementor-widget elementor-widget-text-editor\" data-id=\"acd57f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Features<\/h2>\n<ul>\n \t<li>available in <strong>compact<\/strong> version or with <strong>remote sensor<\/strong>,<\/li>\n \t<li>range -40\/+50 C\u00b0,<\/li>\n \t<li>with optoisolated <strong>Modbus<\/strong> serial,<\/li>\n \t<li>pre-calibrated and quick-to-install spare sensors,<\/li>\n \t<li>&#8220;RILEVA TE&#8221; configuration APP,<\/li>\n \t<li>version with infrared sensor for CO2 &#8211; R744,<\/li>\n \t<li>version with electrochemical sensor for ammonia,<\/li>\n \t<li>version with semiconductor sensor for refrigerated gases, but managed with only 3 codes (each model can be configured via APP for gas groups as indicated below).<\/li>\n<\/ul>\n<table>\n<thead>\n<tr>\n<th scope=\"col\" style=\"width: 15%\">Type<\/th>\n<th scope=\"col\">Supported refrigerant gases (semiconductor version)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Type 1<\/th>\n<td>R-32 &#8211; R-407A &#8211; R-407C &#8211; R-407F &#8211; R-410A &#8211; R-448A &#8211; R-449A &#8211; R-452A &#8211; R-452B \u2013 R-454A &#8211; R-454B &#8211; R-454C &#8211; R-455A &#8211; R-464A &#8211; R-465A &#8211; R-466A &#8211; R-468A &#8211; R-507A<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Type 2<\/th>\n<td>R-22 &#8211; R-134a &#8211; R-404A &#8211; R-450A &#8211; R-513A &#8211; R-1234yf &#8211; R-1234ze &#8211; R-1233zde<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Type 3<\/th>\n<td>R-50 &#8211; R-290 &#8211; R-600A &#8211; R-1150 &#8211; R-1270<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f48247c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f48247c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-900b3b8\" data-id=\"900b3b8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c5dc01d elementor-widget elementor-widget-text-editor\" data-id=\"c5dc01d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span class=\"HwtZe\" lang=\"en\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">A table is available that illustrates the<b> periodic inspections required<\/b>, according to the F-GAS regulations, depending on the <b>gas\/GWP<\/b> used and the <b>amount of refrigerant<\/b> present in the system.<\/span><\/span> <\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-877e576 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"877e576\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f257c85\" data-id=\"f257c85\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0d5c50b elementor-widget elementor-widget-text-editor\" data-id=\"0d5c50b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Rileva TE<strong><br \/><\/strong><\/h2><p>It is possible to interface the gas detectors with a <strong>smartphone<\/strong> and the RILEVA TE APP. With the app you <strong>configure<\/strong> the sensor and its calibration, you can also check the operating status of the GLD mini, the <strong>current gas concentration<\/strong> and any <strong>alarm status<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-eaa9abf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"eaa9abf\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6f08513\" data-id=\"6f08513\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b1d2984 elementor-widget elementor-widget-text-editor\" data-id=\"b1d2984\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Discover more<\/h2><h3>Brochures<\/h3><ul><li><a href=\"https:\/\/www.carel.com\/documents\/10191\/0\/+3000237EN\/f241e142-a8d4-4666-a8e0-33d163114763?version=1.2\" target=\"_blank\" rel=\"noopener\">Refrigerant gas leakage detector &#8211; GLD small series<\/a> (<em>carel.com<\/em>)<\/li><\/ul><h3>Manuals and technical sheets<\/h3><ul><li><a href=\"http:\/\/www.carel.it\/documents\/10191\/0\/+0300047IE\/1398f986-f7d2-40b0-a3ec-ead9273ea510?version=1.6\" target=\"_blank\" rel=\"noopener\">GLD small user manual<\/a> (<em>carel.com<\/em>)<\/li><li><a href=\"http:\/\/www.carel.it\/documents\/10191\/0\/+050003536\/d6c612ed-4322-49b9-967d-3fa9336b6a4d?version=1.5\" target=\"_blank\" rel=\"noopener\">GLD small technical sheet<\/a> (<em>carel.com<\/em>)<\/li><li><a href=\"http:\/\/www.carel.it\/documents\/10191\/0\/+050001415\/93e136d4-143d-447c-b5a5-2acd27c4300b?version=1.2\">Electronic audible and visual alarm technical sheet<\/a>\u00a0(<em>carel.com<\/em>)<\/li><\/ul><h3>Regulations<i><\/i><\/h3><ul><li><a href=\"https:\/\/www.climaset.it\/files\/2024\/03\/F-GAS-regulation-periodic-inspections-revision-1.1.pdf\" target=\"_blank\" rel=\"noopener\">F-GAS gas leak inspection intervals<\/a><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>GLD sensors are designed for industrial refrigeration and air conditioning units that require continuous control and monitoring.<\/p>\n","protected":false},"author":53,"featured_media":17150,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"generate_page_header":"","footnotes":""},"categories":[56,37],"tags":[],"class_list":["post-4558","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-probes-sensors-and-protection-devices","category-regulation","infinite-scroll-item","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-33"],"_links":{"self":[{"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/posts\/4558","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/users\/53"}],"replies":[{"embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/comments?post=4558"}],"version-history":[{"count":20,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/posts\/4558\/revisions"}],"predecessor-version":[{"id":28706,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/posts\/4558\/revisions\/28706"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/media\/17150"}],"wp:attachment":[{"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/media?parent=4558"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/categories?post=4558"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/tags?post=4558"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}