{"id":2908,"date":"2018-01-11T21:09:51","date_gmt":"2018-01-11T20:09:51","guid":{"rendered":"http:\/\/www.climaset.it\/passive-temperature-probes\/"},"modified":"2025-08-06T11:46:20","modified_gmt":"2025-08-06T09:46:20","slug":"passive-temperature-probes","status":"publish","type":"post","link":"https:\/\/www.climaset.it\/en\/passive-temperature-probes\/","title":{"rendered":"Passive temperature probes"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"2908\" class=\"elementor elementor-2908 elementor-1716\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-33f7244 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"33f7244\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7d9f53b\" data-id=\"7d9f53b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-22c4925 elementor-widget elementor-widget-text-editor\" data-id=\"22c4925\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<section data-id=\"33f7244\" data-element_type=\"section\">\n<div>\n<div data-id=\"7d9f53b\" data-element_type=\"column\">\n<div>\n<div data-id=\"22c4925\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n<div>\n<p>The range of <b>passive temperature probes<\/b> includes various models for every type of application.<\/p>\n<p>Probes differentiate themselves depending on the sensor type, the allowed temperature range, the sensible element cap, the degree of protection, etc. <b>Hydronics <\/b>probe models are also available (to be applied directly on piping), and also <b>inserting <\/b>models (to check the temperature of a product).<\/p>\n<p>Here follows an overview on the various passive temperature probes available: for more information <u><b>check the documents on the bottom of the page<\/b><\/u>.<\/p>\n<h2>NTC probes<\/h2>\n<ul>\n<li><i>Temperature range:<\/i><b> <\/b>models -50 \u00b0C up to 150 \u00b0C;<\/li>\n<li><i>Protection rating:<\/i> depends on the selected model;<\/li>\n<li><i>Sensitive element cap: <\/i>plastic, copper, alluminium or steel;<\/li>\n<li><i>Cable lenght:<\/i> available in different lengths;<\/li>\n<\/ul>\n<h2>PTC probes<\/h2>\n<ul>\n<li><i>Temperature range:<\/i><b> <\/b>models up to -30 up to 150 \u00b0C;<\/li>\n<li><i>Protection rating:<\/i> IP67;<\/li><li><i>Sensitive element cap: <\/i>plastic;<\/li>\n<li><i>Cable lenght:<\/i> available in different lengths;<\/li>\n<\/ul>\n<h2>PT100 type probes<\/h2>\n<ul>\n<li><i>Temperature range:<\/i> models from -50 up to 400 \u00b0C;<\/li>\n<li><i>Protection rating: <\/i>IP67; <\/li>\n<li><i>Sensitive element cap:<\/i> steel;<\/li>\n<li><i>Cable lenght:<\/i> 3 meters;<br><\/li>\n<li>Class B sensor;<\/li>\n<\/ul>\n<h2>PT1000 type probes<\/h2>\n<ul>\n<li><i>Temperature range:<\/i> models from -50 up to 350 \u00b0C;<\/li>\n<li><i>Protection rating:<\/i> depends on the selected model;<\/li>\n<li><i>Sensitive element cap:<\/i> plastic, nichel-plated brass or steel;<\/li>\n<li><i>Cable lenght:<\/i> available in different lengths;<\/li>\n<li>Class B sensor;<\/li>\n<\/ul>\n<h2>Thermocouples J and K<\/h2>\n<ul>\n<li><i>Temperature range:<\/i> models from 0 up to 800 \u00b0C;<\/li>\n<li><i>Protection rating:<\/i> IP67;<\/li>\n<li><i>Sensitive element cap: <\/i>steel;<i><br><\/i><\/li>\n<li><i>Cable lenght: <\/i>3 meters; <\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/section>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7fbdc78 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7fbdc78\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-19d2685\" data-id=\"19d2685\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e5232c4 elementor-widget elementor-widget-text-editor\" data-id=\"e5232c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Discover more<\/h2><ul><li><a href=\"https:\/\/www.carel.com\/documents\/10191\/549934\/Temperature_probe.pdf\/bc586dde-f5b5-4232-a565-7babbf00bb34\" target=\"_blank\" rel=\"noopener\"><span title=\"\">Summary table for <\/span><span title=\"\">CAREL passive temperature probes<\/span><\/a><span title=\"\"><em> (carel.com)<\/em><\/span><\/li><li><a href=\"https:\/\/www.carel.it\/documents\/10191\/0\/+030220655\/3a7baa86-1758-45f6-b5f7-bf6d0aa97bd4?version=1.20\" target=\"_blank\" rel=\"noopener\"><span title=\"\">Manual for <\/span><span title=\"\">CAREL passive temperature probes<\/span><\/a><span title=\"\"><em>\u00a0(carel.com)<\/em><\/span><\/li><li><a href=\"https:\/\/www.carel.com\/documents\/10191\/0\/+040010025\/5f37a0c9-37f2-44d3-9c61-2281967169b7?version=1.3\" target=\"_blank\" rel=\"noopener\">Probes and sensors &#8211; Selection and optimal installation guide<\/a><span title=\"\"><em> (carel.com)<\/em><\/span><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Passive temperature sensing probes adapt to all the needs of installers and manufacturers &#8230;<\/p>\n","protected":false},"author":53,"featured_media":26822,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"generate_page_header":"","footnotes":""},"categories":[56,37],"tags":[],"class_list":["post-2908","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-probes-sensors-and-protection-devices","category-regulation","infinite-scroll-item","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-33"],"_links":{"self":[{"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/posts\/2908","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/users\/53"}],"replies":[{"embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/comments?post=2908"}],"version-history":[{"count":3,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/posts\/2908\/revisions"}],"predecessor-version":[{"id":25277,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/posts\/2908\/revisions\/25277"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/media\/26822"}],"wp:attachment":[{"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/media?parent=2908"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/categories?post=2908"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.climaset.it\/en\/wp-json\/wp\/v2\/tags?post=2908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}